﻿<?xml version="1.0" encoding="UTF-8"?>
<ArticleSet>
  <Article>
    <Journal>
      <PublisherName>Tabriz University of Medical Sciences</PublisherName>
      <JournalTitle>Advanced Pharmaceutical Bulletin</JournalTitle>
      <Issn>2228-5881</Issn>
      <Volume>5</Volume>
      <Issue>3</Issue>
      <PubDate PubStatus="ppublish">
        <Year>2015</Year>
        <Month>09</Month>
        <DAY>19</DAY>
      </PubDate>
    </Journal>
    <ArticleTitle>New Validated Stability-Indicating Rp-HPLC Method for Simultaneous Estimation of Atorvastatin and Ezetimibe in Human Plasma by Using PDA Detector</ArticleTitle>
    <FirstPage>385</FirstPage>
    <LastPage>391</LastPage>
    <ELocationID EIdType="doi">10.15171/apb.2015.053</ELocationID>
    <Language>EN</Language>
    <AuthorList>
      <Author>
        <FirstName>S. Ashutosh</FirstName>
        <LastName>Kumar</LastName>
      </Author>
      <Author>
        <FirstName>Manidipa</FirstName>
        <LastName>Debnath</LastName>
      </Author>
      <Author>
        <FirstName>J.V.L.N. Seshagiri</FirstName>
        <LastName>Rao</LastName>
      </Author>
      <Author>
        <FirstName>D. Gowri Gowri</FirstName>
        <LastName>Sankar</LastName>
      </Author>
    </AuthorList>
    <PublicationType>Journal Article</PublicationType>
    <ArticleIdList>
      <ArticleId IdType="doi">10.15171/apb.2015.053</ArticleId>
    </ArticleIdList>
    <History>
      <PubDate PubStatus="received">
        <Year>2015</Year>
        <Month>01</Month>
        <Day>07</Day>
      </PubDate>
    </History>
    <Abstract>Purpose: This paper describes a simple, precise and accurate RP-HPLC method for simultaneous estimation of atorvastatin and ezetimibe in plasma. Methods: The chromatographic separation of the drugs were performed on an X-Terra C8 (4.6 x 150 mm, 3.5 mm), with phosphate buffer [pH 3.5 with Ortho Phosphoric Acid] – acetonitrile 40:60 (v/v) as mobile phase. The detection was performed at 235 nm. The flow rate was maintained at 1.2 mL/min. The run time was 8.0 min. Results: The accuracy and reliability of the method was assessed by evaluation of linearity (5-25 µg/mL for both atorvastatin calcium and ezetimibe), precision (intra-day RSD 0.57 % and inter-day RSD 0.02 % for atorvastatin calcium and intra-day RSD 0.56 % and inter-day RSD 0.1 % for ezetimibe), accuracy (100.08- 100.84 % for atorvastatin calcium and 100.56- 101.00 % for ezetimibe), and specificity, in accordance with ICH guidelines. The LLOQ obtained by the proposed method were 1.294 and 1.384 µg/mL for atorvastatin and ezetimibe respectively. Conclusion: Overall the proposed method was found to be suitable and accurate for the quantitative determination in plasma. The method was effectively separated the drug from plasma.</Abstract>
    <ObjectList>
      <Object Type="keyword">
        <Param Name="value">ICH Guideline</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">Atorvastatin</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">Ezetimibe</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">Plasma</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">RP-HPLC</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">LLOQ</Param>
      </Object>
    </ObjectList>
  </Article>
</ArticleSet>