﻿<?xml version="1.0" encoding="UTF-8"?>
<ArticleSet>
  <Article>
    <Journal>
      <PublisherName>Tabriz University of Medical Sciences</PublisherName>
      <JournalTitle>Advanced Pharmaceutical Bulletin</JournalTitle>
      <Issn>2228-5881</Issn>
      <Volume>3</Volume>
      <Issue>1</Issue>
      <PubDate PubStatus="ppublish">
        <Year>2013</Year>
        <Month>06</Month>
        <DAY>30</DAY>
      </PubDate>
    </Journal>
    <ArticleTitle>High Performance Liquid Chromatographic Analysis of Almotriptan Malate in Bulk and Tablets</ArticleTitle>
    <FirstPage>183</FirstPage>
    <LastPage>188</LastPage>
    <ELocationID EIdType="doi">10.5681/apb.2013.030</ELocationID>
    <Language>EN</Language>
    <AuthorList>
      <Author>
        <FirstName>Petikam</FirstName>
        <LastName>Lavudu</LastName>
      </Author>
      <Author>
        <FirstName>Avula Prameela</FirstName>
        <LastName>Rani</LastName>
      </Author>
      <Author>
        <FirstName>Chepuri</FirstName>
        <LastName>Divya</LastName>
      </Author>
      <Author>
        <FirstName>Chandra Bala</FirstName>
        <LastName>Sekharan</LastName>
      </Author>
    </AuthorList>
    <PublicationType>Journal Article</PublicationType>
    <ArticleIdList>
      <ArticleId IdType="doi">10.5681/apb.2013.030</ArticleId>
    </ArticleIdList>
    <History>
      <PubDate PubStatus="received">
        <Year>2012</Year>
        <Month>10</Month>
        <Day>30</Day>
      </PubDate>
    </History>
    <Abstract>Purpose: A simple RP-HPLC method has been developed and validated for the determination of almotriptan malate (ATM) in bulk and tablets. Methods: Chromatographic separation of ATM was achieved by using a Thermo Scientific C18 column. A Mobile phase containing a mixture of methanol, water and acetic acid (4:8:0.1 v/v) was pumped at the flow rate of 1 mL/min. Detection was performed at 227 nm. According to ICH guidelines, the method was validated. Results: The calibration curve was linear in the concentration range 5–60 µg/mL for the ATM with regression coefficient 0.9999. The method was precise with RSD &amp;lt;1.2%. Excellent recoveries of 99.60 - 100.80% proved the accuracy of the method. The limits of detection and quantification were found to be 0.025 and 0.075 µg/mL, respectively. Conclusion: The method was successfully applied for the quantification of ATM in tablets with acceptable accuracy and precision.</Abstract>
    <ObjectList>
      <Object Type="keyword">
        <Param Name="value">Almotriptan Malate</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">HPLC</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">Validation</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">Tablets</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">Analysis</Param>
      </Object>
    </ObjectList>
  </Article>
</ArticleSet>