Logo-apb
Submitted: 07 Jan 2015
Revision: 02 Apr 2015
ePublished: 19 Sep 2015
EndNote EndNote

(Enw Format - Win & Mac)

BibTeX BibTeX

(Bib Format - Win & Mac)

Bookends Bookends

(Ris Format - Mac only)

EasyBib EasyBib

(Ris Format - Win & Mac)

Medlars Medlars

(Txt Format - Win & Mac)

Mendeley Web Mendeley Web
Mendeley Mendeley

(Ris Format - Win & Mac)

Papers Papers

(Ris Format - Win & Mac)

ProCite ProCite

(Ris Format - Win & Mac)

Reference Manager Reference Manager

(Ris Format - Win only)

Refworks Refworks

(Refworks Format - Win & Mac)

Zotero Zotero

(Ris Format - Firefox Plugin)

Adv Pharm Bull. 2015;5(3): 385-391.
doi: 10.15171/apb.2015.053
PMID: 26504761
PMCID: PMC4616889
Scopus ID: 84983577439
Plum Print visual indicator of research metrics
  • Citations
    • Citation Indexes: 10
  • Captures
    • Readers: 25
see details
  Abstract View: 2153
  PDF Download: 1215

Original Research

New Validated Stability-Indicating Rp-HPLC Method for Simultaneous Estimation of Atorvastatin and Ezetimibe in Human Plasma by Using PDA Detector

S. Ashutosh Kumar 1*, Manidipa Debnath 2, J.V.L.N. Seshagiri Rao 3, D. Gowri Gowri Sankar 4

1 Department of Pharmaceutical Analysis and Quality Assurance, A.K.R.G College of Pharmacy, Nallajerla, West Godavari, 534112, A.P.
2 Department of Pharmaceutics, A.K.R.G College of Pharmacy, Nallajerla, West Godavari, 534112, A.P.
3 Srinivasarao College of Pharmacy, Pothinamallayyapalem, Madhurawada, Visakhapatnam, 530041, A.P.
4 College of Pharmaceutical Sciences, Andhra University, Visakhapatnam, 530003, A.P.
*Corresponding Author: Email: ashu.mpharm2007@gmail.com

Abstract

Purpose: This paper describes a simple, precise and accurate RP-HPLC method for simultaneous estimation of atorvastatin and ezetimibe in plasma.

Methods: The chromatographic separation of the drugs were performed on an X-Terra C8 (4.6 x 150 mm, 3.5 mm), with phosphate buffer [pH 3.5 with Ortho Phosphoric Acid] – acetonitrile 40:60 (v/v) as mobile phase. The detection was performed at 235 nm. The flow rate was maintained at 1.2 mL/min. The run time was 8.0 min.

Results: The accuracy and reliability of the method was assessed by evaluation of linearity (5-25 µg/mL for both atorvastatin calcium and ezetimibe), precision (intra-day RSD 0.57 % and inter-day RSD 0.02 % for atorvastatin calcium and intra-day RSD 0.56 % and inter-day RSD 0.1 % for ezetimibe), accuracy (100.08- 100.84 % for atorvastatin calcium and 100.56- 101.00 % for ezetimibe), and specificity, in accordance with ICH guidelines. The LLOQ obtained by the proposed method were 1.294 and 1.384 µg/mL for atorvastatin and ezetimibe respectively.

Conclusion: Overall the proposed method was found to be suitable and accurate for the quantitative determination in plasma. The method was effectively separated the drug from plasma.